TTR Transformer Turns Ratio Winding Resistance Tester
Huazheng Electric HZ2162 TTR Transformer Turns Ratio Winding Resistance Tester Products Description I. Overview In transformer manufacturing, routine tests (e.g., factory acceptance, installation, maintenance, tap changer adjustments, and preventive diagnostics) require measuring DC resistance...
Huazheng Electric HZ2162 TTR Transformer Turns Ratio Winding Resistance Tester
Product Description
I. Overview
In transformer manufacturing, routine tests (e.g., factory acceptance, installation, maintenance, tap changer adjustments, and preventive diagnostics) require measuring DC resistance and transformation ratio to:
Verify winding joint welding quality and detect inter-turn short circuits.
Validate tap changer contact integrity, positional accuracy, and potential faults (e.g., breaks).
Traditional methods involve cumbersome wiring and multiple instruments, leading to inefficiency and delays.
HZ2162 New Integrated DC Resistance & Transformation Ratio Tester, featuring:
Single-wiring operation: Simultaneously tests transformation ratio and six-phase DC resistance (high/low voltage) without disconnections.
Touchscreen control: Streamlined workflow for rapid results.
II. HZ2162 TTR Transformer Turns Ratio Winding Resistance Tester Tech Data
1.DC Resistance Test
|
Three-Phase Test |
10A, 5A, 1A three ranges. |
|
Test Range |
10A:500.0μΩ~2Ω |
|
5A: 10mΩ~4Ω |
|
|
1A: 1Ω~20Ω |
|
|
Phase-Separated Test |
20A, 10A, 5A, 1A four ranges. |
|
Test Range |
20A:100.0μΩ~1Ω |
|
10A:500.0μΩ~2Ω |
|
|
5A: 10mΩ~4Ω |
|
|
1A: 1Ω~20Ω |
|
|
Resolution |
0.1μΩ |
|
Measurement Accuracy |
class 0.2 |
2.Transformer Ratio
|
Range of Ratio |
1-10000 |
|
Measurement Accuracy |
0.1%(0.8-1000) 0.2% (1000-2000) 0.5% (2000-10000) |
|
Transformer Connection Group |
YY0,YY6,YD1,YD5,YD7,YD11,DD0,DD2,DD4,DD6,DD8,DD10,DY1,DY5,DY7,DY11 |
|
Testing Voltage |
10V/160V |
3. Operating Conditions
|
Instrument Dimensions: 398mm × 262mm × 358mm |
Weight: 19kg |
|
Operating Power Supply: AC 220V |
Power Frequency: 50/60Hz |
|
Ambient Temperature: -10℃ to 50℃ |
Ambient Humidity: ≤85%RH |
III. Key Features
DC Resistance Testing
Broad Compatibility: Tests 10kV/35kV transformers, motors, generators, and conductive components (e.g., relays, wires).
Temperature Compensation: Converts resistance values to standardized temperatures for data comparison.
Safety Protections: Overheat alerts, reverse polarity protection, and audible discharge alarms.
On-Load Tap Switching: Real-time data refresh during measurements without resetting.
Auto-Ranging Current: 6 selectable gears with intelligent load detection.
Transformation Ratio Testing
Precision Inverter Power Supply: Eliminates grid harmonics for accurate results, even with generator inputs.
Three-Phase Output: Accelerates testing, measures inter-phase angles, and auto-detects wiring groups (0–11).
Specialized Transformer Support: Z-type, rectifier, grounding, and electric furnace transformers.
Advanced Protections: Short-circuit, tap misalignment, and reverse voltage safeguards.
Smart Tap Analysis: Auto-calculates ratio, error, and tap positions (supports 99 asymmetric taps).
Intuitive Interface: 7-inch sunlight-readable touchscreen with bilingual (CN/EN) operation.

1. Show Display screen: 7-inch high-definition color touch-screen LCD, digitally adjustable backlight, display operation menu and test results.
2. High voltage end: yellow, green, red, black eight binding posts
3. Low voltage side: yellow, green, red, black eight binding posts
4. Printer: Print the test results after the measurement is completed.
5. AC220V : The power input port of the whole machine is connected to AC 220V power frequency power supply.
6. Protective Earth Post
7. Communication: serial communication
8. USB: U disk storage
Products Cases

Company Profile

Certification

Related Products
Hot Tags: TTR Transformer Turns Ratio Winding Resistance Tester, China TTR Transformer Turns Ratio Winding Resistance Tester manufacturers, suppliers, factory, ttr transfomer turn ratio winding resistance tester, Insulation Resistance Test Equipment, Transformer Capacity Tester, Transformer Short Circuit Impedance Test Equipment, 20kV insulation resistance tester, transformer onload tap changer test set
HZJY-20K 20000V 20kV Digital Insulation Resistance T...
HZ-6300C Transformer Capacity & Loss Tester
12kV Capacitance And Dissipation Factor Test Set
HZ-3150A 50A Transformer DC Resistance Test Equipment
HZCT-100C 0.05% Accuracy Current Transformer CT PT A...
Huazheng HZTTR80A Transformer Turns Ratio TTR Tester
Send Inquiry