3 Phase Sweep Frequency Response Analyser Sfra Test Kit

3 Phase Sweep Frequency Response Analyser Sfra Test Kit

Huazheng HZ-600C 3 Phase Sweep Frequency Response Analyser Sfra Test Kit Products Description System Introduction The Sweep Frequency Response Analyser is designed for power transformers rated 66kV and above, as well as other special-purpose transformers. During operation and transportation, transformers are...

HZ-600C 3 Phase Sweep Frequency Response Analyser Sfra Test Kit

 

Product Description

 

System Introduction

The Sweep Frequency Response Analyzer is designed for power transformers rated 66 kV and above, as well as other special-purpose transformers. During operation and transportation, transformers are susceptible to short-circuit currents and physical impacts, which generate powerful electrodynamic forces. These forces can cause permanent winding deformations (e.g., distortion, swelling, or dislocation), compromising transformer safety.

In compliance with DL/T 911-2016 and IEC 60076-18 standards, this instrument detects winding deformations via Frequency Response Analysis (FRA). It measures the amplitude-frequency response characteristics of each winding and compares results vertically or horizontally to diagnose deformations based on characteristic shifts.

 

Key Technical Features

Non-Invasive Testing: Detects winding deformations (distortion/swelling/displacement) without disassembling the transformer tank.

High Efficiency: Tests a single winding in ≤2 minutes with three-phase automation.

Precision: Frequency accuracy >0.001% with digital synthesis for enhanced stability.

Safety: 5000V voltage isolation protects connected computers.

Advanced Analysis: Simultaneously loads 9 curves, auto-calculates parameters, and provides diagnostic conclusions.

Standards Compliance: Meets DL/T911-2016/IEC60076-18 requirements.

User-Friendly Software: One-click operation after parameter setup; intuitive interface with clear analysis/save/report functions.

 

Technical Specifications

Parameter Specification
Test Method Frequency Response (Three-phase automation)
Test Speed 1–2 minutes per winding
Output Voltage Vpp 25V (auto-adjusted)
Output Impedance 50Ω (Standard)
Input Impedance 1MΩ (50Ω matching for response channel)
Frequency Range 10Hz–2MHz
Frequency Accuracy 0.001%
Sweep Mode Linear/Logarithmic (adjustable points/interval)
Data Display Magnitude-Frequency Curve
Dynamic Range -100dB to 20dB
Power Supply AC 100–240V, 50/60Hz
Weight 3.8kg

 

Software Features

Compatibility: Windows 2000/XP/7/8/10/11.

Data Management: Database storage for structured data handling.

Diagnostic Tools: Supports 9-curve comparison with automated deformation diagnosis.

Reporting: Auto-saves data; exports Word/JPG reports (requires Office suite).

User-Centric Design:

Minimal manual input with preset options.

One-click operation post cable connection.

Intuitive interface for analysis, saving, and reporting.

 

 

FAQ

 

1. When can I get a price quote?

You can contact us online or submit an inquiry. We typically provide a quote within 24 hours after receiving your request.

 

2. How do you handle after-sale service for overseas customers?

For issues occurring with our products, we offer:

12-month warranty coverage (see details below).

Online technical guidance to troubleshoot problems remotely.

Replacement parts shipped promptly based on your needs.

On-site support (if required): Our engineers can travel abroad to resolve critical issues.

IMG20241121162722

3. What is the warranty period?

Our standard warranty period is 12 months (1 year). During this time, we provide:

Free technical support.

Replacement parts for manufacturing defects.

Solutions tailored to your specific issue.

 

Products Cases

 

HZ-20A04

 

Company Profile

 

af7e9172c2e3db1e6c4b786d81dd1ea7

 

Certification

 

Manufacturing-Price-Portable-Automatic-Current-Transformer-CT-PT-Testing-System 1

 

 

Related Products

 

 

product-750-1077

 

 

 

 

 

 

 

Send Inquiry

(0/10)

clearall