HZJD-2 Transformer Oil Tan Delta and Resistivity Tester Products Description I. Overview The Insulating Oil Dielectric Loss and Electrical Resistivity Tester complies with the Chinese National Standard GB/T5654-2007 ( Liquid insulating materials - Measurement of relative permittivity, dielectric...

HZJD-2 Transformer Oil Tan Delta and Resistivity Tester

 

Product Description

 

I. Overview
The HZJD-2 Insulating Oil Dielectric Loss and Electrical Resistivity Tester complies with the Chinese National Standard GB/T5654-2007 (Liquid insulating materials - Measurement of relative permittivity, dielectric dissipation factor and d.c. resistivity). It is primarily designed for measuring the dielectric loss factor (tan δ) and DC resistivity of liquid insulating media, such as transformer oil.

 

II. Key Features & Functions

Standardized Test Cell: Employs a GB/T5654-2007 compliant three-electrode structure (2mm gap) to minimize stray capacitance and leakage effects on tan δ measurements.

Precise Temperature Control: Uses medium-frequency induction heating with a PID algorithm for non-contact, uniform, rapid heating. Temperature is strictly maintained within the preset range (0–125°C).

Stable Reference Capacitor: Features an internal SF6 gas-filled three-electrode capacitor, ensuring tan δ and capacitance stability unaffected by ambient temperature/humidity, guaranteeing long-term accuracy.

Stable AC Power Supply: Employs AC-DC-AC conversion, eliminating the impact of mains voltage and frequency fluctuations on measurement accuracy. Operates reliably even with generator power.

Comprehensive Safety Protections:

Rapid shutdown and warnings for over-voltage, over-current, or high-voltage short circuits.

Warnings for sensor failure or disconnection.

Built-in temperature-limiting relay in the heating furnace; stops heating above 120°C.

Flexible Parameter Settings: Easily adjustable test temperature (0–125°C), AC voltage (500–2200V RMS), and DC voltage (0–500V).

User-Friendly Interface: Clear LCD display with intuitive Chinese menu prompts guides users through automated testing, storage, and printing.

Integrated Real-Time Clock: Automatically saves, displays, and prints test dates/times with results.

Test Cell Calibration: Enables assessment of cell cleanliness and assembly via electrode capacitance and tan δ measurement. Calibration data is stored for accurate calculation of relative permittivity and DC resistivity.

 

III. Technical Specifications

Parameter Specification
Power Supply AC 220V ±10%, 50Hz/60Hz ±1%
Power Consumption 100W
Dimensions (WxDxH) 500 mm x 360 mm x 420 mm
Weight 22 kg
   
Test Temperature Range: 0°C to 125°C
Accuracy: ±0.5°C
Test Voltages AC (RMS): 500V to 2200V, Continuously adjustable, 50Hz
DC: 0V to 500V, Continuously adjustable
   
Measurement Ranges  
Capacitance (Cx) 5 pF to 200 pF
Relative Permittivity (εᵣ) 1.000 to 30.000
Dielectric Loss Factor (tan δ) 0.00001 to 100
DC Resistivity (ρ) 2.5 MΩ·m to 20 TΩ·m
   
Measurement Accuracy  
Capacitance (Cx) ±(1% of reading + 0.5 pF)
Relative Permittivity (εᵣ) ±1% of reading
Dielectric Loss Factor (tan δ) ±(1% of reading + 0.0001)
DC Resistivity (ρ) ±10% of reading
   
Resolution  
Capacitance (Cx) 0.01 pF
Relative Permittivity (εᵣ) 0.001
Dielectric Loss Factor (tan δ) 0.00001

 

 

Products Cases

 

HZ-20A04

 

Company Profile

 

af7e9172c2e3db1e6c4b786d81dd1ea7

 

Certification

 

Manufacturing-Price-Portable-Automatic-Current-Transformer-CT-PT-Testing-System 1

 

 

Related Products

 

 

product-750-1077

 

 

 

 

 

 

 

Hot Tags: hzjd-2 transformer oil tan delta and resistivity tester, China hzjd-2 transformer oil tan delta and resistivity tester manufacturers, suppliers, factory, insulating oil power factor tester, Oil Tan Delta Tester, Oil Dielectric Loss And Resistivity Tester, oil tan delta and resistivity tester, dielectric oil power factor tester

Send Inquiry

(0/10)

clearall