HZZ4000 Digital Power Quality And Energy Analyzer

Huazheng HZZ4000 Power Quality Analyzer is a comprehensive test instrument developed by our company, specifically designed for field testing of three-phase systems. It is a multi-functional, intelligent device with an intuitive man-machine interface. The analyzer is user-friendly, featuring a large LCD screen with high resolution, and it supports both Chinese and English interfaces. Its shock-proof shell ensures durability in various environments. The HZZ4000 can simultaneously measure four channels of current (three-phase ABC and neutral wire current) and four channels of voltage (three-phase ABC voltage and neutral-to-ground voltage). It provides detailed measurements, including the peak values of current and voltage, maximum/minimum values over a period, three-phase imbalance factor, short-term voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor, displacement power factor, total harmonic distortion, and harmonic levels. The analyzer displays real-time waveforms and harmonic ratio bar charts for current and voltage. It can dynamically capture instantaneous changes in voltage and current, monitor starting currents, and track power parameters. The device also generates alarm notifications, creates long-term trend charts, and stores test data for future analysis.

HZZ4000 Digital Power Quality And Energy Analyzer

 

 

Products Description

 

I. Introduction

In modern power applications, large power equipment and increasingly complex power grid faults are becoming more prevalent. As industrial development continues, the demand for higher quality electric energy is rising. To address these challenges, we provide the HZZ4000 Power Quality Analyzer, which allows for faster and more accurate troubleshooting of complex power systems, as well as more comprehensive and systematic monitoring and maintenance of power quality parameters."

"The HZZ4000 Power Quality Analyzer utilizes a dual-processor architecture with DSP and ARM processors. The DSP is responsible for data collection and algorithm processing, while the ARM handles communication protocols and man-machine interface tasks. Analog signal acquisition is achieved through two ADC chips from ADI, with a 16-bit resolution and 4-channel synchronous sampling. The highest sampling rate reaches 1 MSPS, ensuring accurate channel measurements and data integrity, without missing any transient changes in the grid. This enables precise detection of rapid waveform rises, drops, and instantaneous interruptions."

"With a DSP working frequency of over 200 MHz, the analyzer can monitor the power grid in real time and dynamically adjust the sampling frequency to ensure synchronization with the power frequency. The device features a 5.6-inch LCD color display with a resolution of 640 x 480 pixels, offering clear visual distinctions between phase parameters, waveforms, vector diagrams, and harmonic ratios. This helps users more efficiently and intuitively understand the state of the power grid."

"The analyzer's built-in flash memory can store up to 60 screenshots, 150 transient voltage/current waveforms, and 12,800 alarm entries. It also features a starting current detection mode, which continuously captures starting current waveforms for up to 100 seconds. A built-in 2GB memory card stores trend curve records, capturing data for 20 parameters (selectable based on needs) every five seconds. These trend curve records can be kept for up to 300 days."

"The Power Quality Analyzer, also known as the Intelligent Three-Phase Power Quality Analyzer or Multifunctional Power Quality Analyzer, integrates the functions of a harmonic analyzer, phase volt-ampere meter, and electrical parameter tester. It is suitable for use in industries such as electricity, petrochemicals, metallurgy, railways, mining, scientific research institutions, and metrology departments. It is especially valuable for comprehensive analysis and diagnostics of voltage, current, power, harmonic, and phase electrical parameters.

II.Technical specification

2.1. Base condition and working condition

Influence factor

Test item

Base condition

Working condition

Environment temperature

All parameters

(23±2)°C

-10°C~ 40°C

Relative humidity

All parameters

40%~ 60%

<80%

Phase-to-neutral voltage

All parameters

(100±1%)V

1.0V~ 1000V

Phase-to-phase voltage

True RMS phase-to-phase voltage

(200±1%)V

1.0V~ 2000V

Current

True RMS current

(5±1%)A

10mA~ 6000A

Network frequency

All parameters

50Hz±0.1Hz

40Hz~ 70Hz

Phase shift

Active power and active energy

Cosφ=1

Cosφ: 0.2~ 1.0

Reactive power and reactive energy

Sinφ=1

Sinφ: 0.2~ 1.0

Harmonic

All parameters

<0.1%

0.0%~ 100%

Voltage unbalance

All parameters

<10%

0.0%~ 100%

Working voltage of device

All parameters

DC9.8V±0.1V

DC9.5V~ 10.5V

External electric field,

magnetic field

All parameters

Should be avoided

Measured lead position

Measured related parameters of current

Tested wire at the center of clamp.

2.2. General specification

Power supply

Rechargeable lithium-ion battery packs 9.6V, backup charger.

Battery indicator

Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.

Power consumption

Current consumption of normal test 490 mA, continuous working for 10 hours.

Display mode

LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm.

Size of clamp

FR008 small sharp current clamp: 8mm×15mm;

FR020 circle current clamp: 20mm×20mm;

FR050 circle current clamp: 50mm×50mm.

FR300R Flexible Coil Current Sensor (with Integrator) : Ф300mm

Instrument dimensions

L×W×H: 277.2mm × 227.5mm × 153mm.

Number of channels

4U/4I.

Phase-to phase voltage

1.0V~2000V.

Phase-to-neutral voltage

1.0V~1000V.

Current

FR008 current clamp: 10mA~10.0A;

FR020 current clamp: 0.10A~100A;

FR050 current clamp: 1.0A~1000A;

FR300R Flexible Coil Current Sensor (with Integrator) : 10A ~ 6000A

Frequency

40Hz~70Hz.

Parameters of electricity

W, VA, Var, PF, DPF, cosφ, tanφ.

Energy parameters

Wh, Varh, Vah.

Harmonic

Order 0~50.

Total harmonic distortion

Order 0~50, each phase.

Expert mode

Yes.

Number of Transient records

150 sets.

Voltage flicker

Yes.

Starting current mode

Yes, 100 seconds.

3 phases unbalance

Yes.

Record

300 days(simultaneous recording 20 parameters, record one point every 5 seconds).

Min/Max recorded value

Measurement of maximum and minimum values over a period of time.

Alarm

40 different types of parameter selections, 12,800 sets alarm logs.

Peak

Yes.

Phasor diagram display

Automatically.

Capacity of snapshots

60.

Menu language

English/Chinese.

Communication

USB.

Automatic switching off

When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.

In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.

Backlight function

Yes, suitable for use at night and dark place.

Weight

Host: 1.6kg (with battery).

FR008 small sharp current clamp: 168g×4;

FR020 circle current clamp: 252g×4;

FR050 circle current clamp: 463g×4;

FR300R Flexible Coil Current Sensor (with Integrator) : 280g×4;

Test wires and power adapter: 800g;

Total weight: about 10.8kg (with packaging).

Length of voltage test wire

3m.

Length of current sensor wire

2m.

Working temperature and humidity

-10°C~40°C; below 80%Rh.

Storage temperature and humidity

-10°C~60°C; below 70%Rh.

Input impedance

Input impedance of test voltage: 1MΩ.

Withstand voltage

Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.

Insulation

Between instrument wiring and shell ≥10MΩ.

Structure

Double insulation, with insulation vibration-proof sheath.

Safely rules

IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.

 

III. Function

3.1. Basic function

★ Waveform real-time display (4 channels voltage/4 channels current).

★ True RMS values of voltages and currents.

★ The DC components of voltages.

★ Peak current and voltage values.

★ Minimum and maximum half-cycle RMS current and voltage values.

★ Phasor diagram display.

★ Measurement of each harmonic up to order 50.

★ Bar charts show harmonic ratios of current and voltage of each phase.

★ Total harmonic distortion (THD).

★ Active, reactive, apparent power, by phase and cumulative.

★ Active, reactive, apparent energy, by phase and cumulative.

★ Transformer K factor.

★ Power factors (PF) and displacement factors (DPF or COSΦ).

★ Short-term voltage flicker (PST).

★ Three phase unbalance(current and voltage).

3.2. Capture function

Transient capture function

Monitoring instantaneous change of power grid voltage current parameters, including the voltage current fluctuations, voltage current surge, sag and short supply interruption, temporary overvoltage, impact current and Current voltage instantaneous distortion. Instruments can store 150 sets of transient waveform at the same time.

Starting current monitoring

Monitoring surge current of line and the startup current when electrical equipment is starting, help to correctly design capacity. Can be display the RMS rising / falling curve In the startup process, the envelope curve of startup current, waveform of 4 channels current and 4 channels voltage. Recording about 100s after trigger, storage the current /voltage instantaneous and waveform curve of each cycle in 100s.

Trend chart recording and storing function

Store all the test parameters of basic test functions (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms, Athd, Acf, Aunb, KF,W, VAR, VA, PF, COSφ, TANφ),50 voltage harmonics, 50 current harmonics. And create the trend curve. Record data for a long time according to need(concurrent selection 20 parameters to record data for once every five seconds, you can record about 300 days.).

Alarm function

Set the limit values according to need, monitoring the values whether overshoot, if overshoot will generate an alarm log, such as: voltage, current, unbalance, harmonic ratio, frequency, active power, total harmonic distortion. You can configure 40 different alarms, each group can set different monitoring parameters (including 50 harmonics, total of 123 different parameters) and limit values, also can set the shortest time of overshoot. The log can contain up to 12,800 alarms.

Snapshot function

Any screen can be saved (screen snapshot), at the same time automatically records the time and test mode. Such as can save voltage and current waveform, harmonic bar chart, phasor diagram etc. It can save a maximum of 60 screen snapshot.

3.3. Other functions

Communication function

Communicate with computer via USB; Monitoring software can display waveform of power quality analysis, read of the transient waveform, trend chart recording, alarm log, screenshots, and display on the computer.

Setting function

The user can configuration of the time and date, configuration of the screen contrast and brightness, definition of each phase curve colors'.

Choice of type of connection to the net work.

Configuration of the type of the current sensors and voltage ratios.

Select Chinese menu or English menu.

Help menu in Chinese/English

Every stage of operation can press the "help" key to obtain relevant information.

Power Quality And Energy Analyzer 2new

Power Quality And Energy Analyzer 3new

Power Quality And Energy Analyzer 4new

Power Quality And Energy Analyzer 5new

Power Quality And Energy Analyzer 6new

Power Quality And Energy Analyzer 7new

Power Quality And Energy Analyzer 8new

Power Quality And Energy Analyzer 9new

Power Quality And Energy Analyzer 10new

Power Quality And Energy Analyzer 1newjpg

 

 

FAQ

 

1. When can I get a price quote?

You can contact us online or submit an inquiry. We typically provide a quote within 24 hours after receiving your request.

 

2. How do you handle after-sale service for overseas customers?

For issues occurring with our products, we offer:

12-month warranty coverage (see details below).

Online technical guidance to troubleshoot problems remotely.

Replacement parts shipped promptly based on your needs.

On-site support (if required): Our engineers can travel abroad to resolve critical issues.

IMG20241121162722

3. What is the warranty period?

Our standard warranty period is 12 months (1 year). During this time, we provide:

Free technical support.

Replacement parts for manufacturing defects.

Solutions tailored to your specific issue.

 

Products Cases

 

HZ-20A04

 

Company Profile

 

af7e9172c2e3db1e6c4b786d81dd1ea7

 

Certification

 

Manufacturing-Price-Portable-Automatic-Current-Transformer-CT-PT-Testing-System 1

 

 

Related Products

 

 

product-750-1077

 

 

 

 

 

 

Hot Tags: HZZ4000 Digital Power Quality And Energy Analyzer, China HZZ4000 Digital Power Quality And Energy Analyzer manufacturers, suppliers, factory, ASTM D611 Anilne Point Tester, ASTM D86 Distillation Apparatus, motor oil abrasion tester, affordable other products, device for measuring earth resistance, astm d86 distillator

Send Inquiry

(0/10)

clearall