80kV 3mA DC High Potential Hipot Tester
The DC High Voltage Generator is not just about power; it’s about precision. With adjustable output settings, users can fine-tune the voltage to meet specific requirements, ensuring optimal performance for every application. Whether you’re conducting experiments, performing quality control tests, or engaging in educational demonstrations, this generator delivers consistent and reliable results.The generator uses AC 220 V power supply (AC220V±10%, 50 hz±1%), the ripple factor is less than 0.5%, and can be used for all-weather at the site .
Products Description
The 80kV 3mA DC High Potential Hipot Tester is a professional device for testing the DC withstand voltage and leakage current of power equipment, electrical components, and insulation materials. It can accurately identify insulation defects.
Customizable Options
Customizable Output Voltage Range (≤80kV, different ranges)
Customizable Output Current Range (≤3mA or higher)
Customizable Test Time, Boost Rate, and Automatic Discharge Program
Customizable User Interface Language (Chinese/English/Multilingual)
High Potential Hipot Tester Technical Parameters
|
Voltage (KV)/mA Current (mA) |
Control Box |
High-Voltage Unit |
|||
|
Rated Voltage |
Size (mm) |
Weight kg |
Size (mm) |
Weight kg |
|
|
80/2-5 |
80KV |
310 * 250 * 230 |
6kg |
490*260*220 |
8kg |
High Potential Hipot Tester Common Fault And Solution
|
Fault Phenomenon |
Solution |
|
|
1 |
Over-current often occurs during zinc oxide arrester tests. |
1. Whether caused by too rapid voltage increase at turning point. Adjust the knob slowly at turning point. |
|
2 |
Unstable current during capacitive tests. |
1.Whether caused by HV equipment to test 10 kV cable. 2. Sudden unstable currents are mostly caused by break of inner wire in fast loading multi-core cable. |
|
3 |
Voltage increases from non-zero state after turning knob clockwise |
Caused by inner shield of line 1 and 2, break of line 4 and 5 in fast loading multi-core cable |
|
4 |
Picture missing on LCD |
Partial damage of LCD, return to factory for replacement. |
|
5 |
No current at rated voltage |
Check whether output core wire is broken |
|
6 |
Ammeter data exists in control box, but there is no current display |
The clip should be suspended in the air. |



Products Cases

Company Profile

Certification

Related Products

FAQ
Q: What are the test objects suitable for this equipment?
A: Suitable for DC withstand voltage and leakage current testing of cables, transformer windings, motor insulation, high-voltage components, and insulating materials.
Q: Is the operation complex? Is it required by professional personnel?
A: The interface is intuitive, and the operation process is clear. General technicians can operate it independently after simple training.
Q: Is the equipment safe? Are there any protective measures?
A: It has overvoltage, overcurrent, automatic discharge, and emergency stop protection, meeting high-voltage testing safety requirements.
Q: What is the minimum order quantity?
A: The MOQ for the standard model is 1 unit. Sample orders are supported.
Q: What is the delivery time?
A: Standard models typically take 7–15 working days; customized models depend on configuration.
Send Inquiry