120kV 3mA DC High Voltage Test Machine
DC High Voltage Hipot Test Machine When installing or removing the plug, please hold the metal ring securely. It is strictly prohibited to pull on the wire directly. In conclusion, the DC High Voltage Test Machine is more than just equipment; it is a gateway to innovation and discovery. Elevate your projects and experiments with a tool that combines power, safety, and precision. Experience the future of high-voltage generation today!
Products Description
The 120kV 3mA DC High Voltage Test Machine is a DC high voltage test device used for withstand voltage and leakage current testing of power equipment, insulation materials and high voltage components.
Quality Assurance
Core Components: High-voltage transformers, voltage multiplier modules, and insulation supports are all made of high-voltage resistant and aging-resistant materials. Insulation levels and creepage distances meet industry standards.
Standardized Production: The entire unit is assembled according to standard processes, and the high-voltage, control, and protection modules are tested separately.
Comprehensive Factory Testing: Each unit undergoes no-load testing, rated load testing, overcurrent/overvoltage protection verification, and safety interlock testing.
DC High Voltage Test Machine Safety Precautions
Note:
When installing or removing the plug, always hold the metal ring firmly. Do not pull the cable directly.
Safety Notice:
To ensure operator safety during discharge, the discharge rod must be securely and correctly connected. The discharge system includes:
Ground jack
Discharge tip
Ground lead
During discharge, keep the rear end of the grounding lead angled away from the test object to prevent arcing between the ground and the sample.
Power Main Switch:
Do not use the main power switch to directly shut down high voltage. Always turn off the High Voltage Switch first, then switch off the main power.
High Voltage Switch:
Turn on the high voltage switch only after the system is ready for testing. After the test, switch it off first before cutting off the main power.
Power Supply Check:
Before operation, confirm that the input power supply matches the rated voltage.
After testing, ensure the test object is fully discharged for at least 1 minute before handling.
DC High Voltage Test Machine Technical Parameters
|
Voltage (KV)/mA Current (mA) |
Control Box |
High-Voltage Unit |
|||
|
Rated Voltage |
Size (mm) |
Weight kg |
Size (mm) |
Weight kg |
|
|
120/2-5 |
120KV |
310 * 250 * 230 |
7kg |
600 * 260 * 220 |
10kg |
|
output polarity |
Negative polarity, no-voltage start, linear continuous adjustment |
||||
|
working power supply |
50HZ AC220V±10% |
||||
|
voltage error |
0.5%±2,minimum solution 0.1KV |
||||
|
current error |
0.5%±2,minimum solution 0.1µA |
||||
|
ripple factor |
better than 0.5% |
||||
|
voltage stability |
Random flunctuation , grid change is 10% , the flunctuation <=0.5% |
||||
|
working manner |
Interval working, less than 30 minutes under rated load |
||||
|
working condition |
Temperature: 0-40℃, humidity: less than 90% |
||||
|
storage condition |
Temperature: -10℃~40℃, humidity: less than 90% |
||||
|
altitude |
Lower than 3000 m |
||||



Products Cases

Company Profile

Certification

Related Products
Hot Tags: 120kV 3mA DC High Voltage Test Machine, China 120kV 3mA DC High Voltage Test Machine manufacturers, suppliers, factory, digital dc high voltage generator, dc hipot test kit, 120 kv dc hipot xlpe cable testing, intelligent dc high voltage test equipment, dc withstand voltage tester, hi pot tester hzzgf 200kv