HZXB(L)-200kVA/50kV Induction Series AC Resonance Test System I. Testing object AC withstand voltage test of 22kV/600MW thermal power generator, capacity ≤0.2158uF, test frequency 50Hz, test voltage 47kV, test time 1min II. Main technical parameters and functions Rated capacity:200kVA; Rated...

 

200kVA/50kV Induction Series AC Resonance Test System

 

I.Testing object

AC resonance withstand voltage test of 22kV/600MW thermal power generator, capacity ≤0.2158uF, test frequency 50Hz, test voltage 47kV, test time 1min

 

II.Main technical parameters and functions

Rated capacity:200kVA;

Rated voltage:50kV;

Rated current:4A;

Operating frequency:power frequency 50Hz;

Output voltage waveform distortion rate:≤0.5%;

Allow continuous working hours:5min(under rated load);

Temperature rise after continuous operation for 5min under rated load: ≤65K;

Device's own quality factor:Q≥10;

System measuring accuracy:virtual value 1.5 class;

Output power:single 220V,50Hz;

Over current, over pressure and flashover protection are provided for the testing object;

Environment temperature:-100C –50 0C

Relative humidity:≤90%RH,Altitude≤1000m;

 

System configuration and parameters

Excitation transformer JLB-20kVA/5kV/0.4kV 1 set

Rated capacity:20kVA;

Input power:220V,single phase;

Output voltage:3kV

Type:Dry type

Weight: about 125kg;

Temperature rise of coil to air after

1 min rated operation:≤65K;

Operating bench HZXB-(L)-20kVA/380V (Including voltage regulator) 1 Set

Rated capacity:20kVA;

product-379-498Input voltage:380V

Output voltage:0~250V;

Protection function: zero, overcurrent, overvoltage and flashover protection;

Weight:about 100kg;

Adjustable reactor DK(L)-200kVA/50kV 1 Set

product-414-443Rated capacity:200KVA;

Rated voltage:50kV;

Rated current:4A;

Adjustable inductance:47H~127H;

quality factor:Q≥10;

Type: Dry type, adjustable with iron core:;

Quantity:1 set;

Weight:about 180Kg ;

High voltage divider FRC-50kV 1 Set

Rated voltage:50kV

Testing accuracy:AC RMS 1.5 class;

Dielectric loss:tgσ≤0.5%;

The ratio of divided voltage:1000:1,accuracy:≤1.0%;

Weight:about 10Kg;

Compensating capacitor BC-50kV/0.08uF 1 Set

Rated voltage:50kV;

High voltage capacity:0.08uF

Weight:15kg

VI. System equipments List

 

List of equipment configuration

No.

Name

Model

Unit

quantity

Comment

1

Excitation transformer

JLB-20kVA/5kV/0.4kV

set

1

 

2

Control Bench

HZXB-(L)-20kVA/380V

set

1

 

3

Adjustable reactor

DK-(L)-200kVA/50kV

set

1

 

4

Divider

FRC-50kV

set

1

 

5

compensating capacitor

BC-50kV/0.08uF

set

1

 

6

Testing Line

 

set

1

 

 

 

 

FAQ

 

1. When can I get a price quote?

You can contact us online or submit an inquiry. We typically provide a quote within 24 hours after receiving your request.

 

2. How do you handle after-sale service for overseas customers?

For issues occurring with our products, we offer:

12-month warranty coverage (see details below).

Online technical guidance to troubleshoot problems remotely.

Replacement parts shipped promptly based on your needs.

On-site support (if required): Our engineers can travel abroad to resolve critical issues.

IMG20241121162722

3. What is the warranty period?

Our standard warranty period is 12 months (1 year). During this time, we provide:

Free technical support.

Replacement parts for manufacturing defects.

Solutions tailored to your specific issue.

 

Products Cases

 

HZ-20A04

 

Company Profile

 

af7e9172c2e3db1e6c4b786d81dd1ea7

 

Certification

 

Manufacturing-Price-Portable-Automatic-Current-Transformer-CT-PT-Testing-System 1

 

 

Related Products

 

product-750-1069

 

 

 

 

 

 

 

Hot Tags: 200kva/50kv induction series ac resonance test system, China 200kva/50kv induction series ac resonance test system manufacturers, suppliers, factory, variable frequency resonant test set, cables ac resonant test system, AC Resonance Test System

Send Inquiry

(0/10)

clearall