
Transformer Oil DGA Dissolved Gas Chromatography Analyzer
Huazheng HZGC-1212A Transformer Oil DGA Dissolved Gas Chromatography Analyzer Products Description Features of HZGC-1212A Gas chromatograph : ★ It adopts advanced technology of 100Mbps/1000Mbps Ethernet communication interface and built-in IP protocol stack, enabling the instrument to achieve long-distance data...
HZGC-1212A Transformer Oil DGA Dissolved Gas Chromatography Analyzer
Products Description
Features of HZGC-1212A Gas chromatograph:
★ It adopts advanced technology of 100Mbps/1000Mbps Ethernet communication interface and built-in IP protocol stack, enabling the instrument to achieve long-distance data transmission through the enterprise's internal LAN and the internet; facilitating laboratory setup, simplifying laboratory configuration, and convenient data management.
★ The instrument is internally designed with three independent IP addresses, which can be connected to the workstation (at the laboratory site), dedicated computers (such as quality inspection department, production department), and executive computers (such as environmental protection bureau, technical supervision bureau). Real-time monitoring of instrument operation and analysis data results is possible.
★ The dedicated workstation equipped with the instrument can simultaneously support multiple chromatographs for data processing and instrument reverse control, simplifying document management.
★ The instrument can be connected to the manufacturer via the internet, enabling remote diagnostics, remote updates, etc. (user configuration required).
★ The instrument is equipped with an 8-inch color LCD touchscreen, supporting hot swapping and can be used as a handheld controller.
★ The instrument operates in parallel with multiple processors, making it more stable and reliable. It can be optionally equipped with a variety of high-performance detectors such as FID, TCD, ECD, FPD, and NPD, with a maximum installation of three detectors simultaneously to meet the analysis requirements of complex samples.
★ The instrument adopts a modular design structure, making it easy and convenient for maintenance.
★ The new microcomputer temperature control system provides high temperature control accuracy, superior reliability, and anti-interference performance. It has eight completely independent temperature control outputs, enabling sixteen-step program heating. It also features an automatic back-opening system for the column oven, improved near-room temperature control capability, and faster temperature ramp rates.
★ The chromatograph has a built-in low-noise, high-resolution 24-bit AD circuit, with baseline storage and subtraction functions.
★ The standard workstation is suitable for operating systems such as WinXP, Win2000, Win7, Win8, Win10.
★ The chromatograph's microcomputer system with fully independent intellectual property rights has the standard MODBUS/TCP protocol and can be integrated with DCS systems.
Main technical specifications:
● Operation display: 8-inch high-definition color LCD touchscreen, can be used as a handheld controller.
● Temperature control zones: 8.
● Temperature control range: 4℃ to 450℃ above room temperature, increment: 1℃, accuracy: ±0.1℃.
● Program temperature ramp stages: 16 stages (expandable).
● Temperature ramp rate: 0.1 to 60℃/min.
● Gas flow control: Precision mechanical valve flow control.
● External events: 8 channels; auxiliary control outputs: 2 channels.
● Sampler types: Packed column injection, capillary injection, six-port valve gas injection, automatic sampler.
● Number of detectors: 3 (maximum); options include FID, TCD, ECD, FPD, and NPD.
● Injection initiation: Manual or automatic (optional).
● Communication interface: Ethernet: IEEE802.3.1.3.2 Detector technical specifications
1. Hydrogen Flame Ionization Detector (FID)
● Detection limit: ≤5×10-12g/s(cetane/isooctane)
● Baseline noise: ≤0.05PA
● Baseline drift: ≤0.2PA/30min
● Linear range: ≥106
2. Thermal Conductivity Detector (TCD)
● Sensitivity: S≥10000mV•ml/mg(benzene/toluene) (with amplification 1, 2, 3, 4 times optional)
● Baseline noise: ≤20μV
● Baseline drift: ≤30μV/30min
● Linear range: ≥104
3. Electron Capture Detector (ECD)
● Detection limit: ≤1×10-13g/ml (propyl BHC-isoctane solution)
● Baseline noise: ≤0.03mV
● Baseline drift: ≤0.2mV/30min
● Linear range: 103
● Radioactive source: 63Ni
4. Flame Photometric Detector (FPD)
● Detection limit: (S)≤5×10-11g/s,
(P)≤1×10-12g/s; (methyl parathion - anhydrous ethanol solution)
● Baseline noise: ≤3×10-13A
● Baseline drift: ≤2×10-12A/30min
● Linear range: ≥102 for sulfur, ≥103 for phosphorus
5, nitrogen and Phosphorus detector (NPD)
● Detection limit: (N)≤5×10-13g/s,
(P)≤5×10-13g/s; (methyl parathion - anhydrous ethanol solution)
● Baseline noise: ≤5×10-13A
● Baseline drift: ≤2×10-12A/30min
● Linear range: N ≥102, P ≥102
|
Detector |
Gas action |
Gas name |
Purity |
|
FID |
Carrier gas |
N2 or He |
Not less than 99.999% |
|
TCD |
Carrier gas |
He, H2, or N |
Not less than 99.999% |
|
ECD |
Carrier gas |
N2(most appropriate) |
Not less than 99.999%(Deoxygenated) |
|
NPD |
Carrier gas |
N2 or He |
Not less than 99.999% |
|
FPD |
Carrier gas |
N2 or He |
Not less than 99.999% |
|
Tail Blow |
N2 |
Not less than 99.99% |
|
|
Gas |
H2 |
Not less than 99.99% |
|
|
Auxiliary Gas |
Air |
Clean, dry |
|
Why Choose Us
Customized solutions
We understand that each client's needs are unique, so we can tailor solutions to meet your specific requirements to meet individual client needs.

Quality control
We strictly abide by the international quality management system and strictly control every link from raw material procurement, production process, product quality inspection, etc. to ensure the stability and reliability of our products and services.

Our service
The company has a professional sales team to provide you with high-quality pre-sales consulting services. During the order production process, customers can communicate with us at any time to understand the production progress. At the same time, we provide high-quality after-sales service to meet the different needs of customers.

FAQ
1. When can I get a price quote?
You can contact us online or submit an inquiry. We typically provide a quote within 24 hours after receiving your request.
2. How do you handle after-sale service for overseas customers?
For issues occurring with our products, we offer:
12-month warranty coverage (see details below).
Online technical guidance to troubleshoot problems remotely.
Replacement parts shipped promptly based on your needs.
On-site support (if required): Our engineers can travel abroad to resolve critical issues.
3. What is the warranty period?
Our standard warranty period is 12 months (1 year). During this time, we provide:
Free technical support.
Replacement parts for manufacturing defects.
Solutions tailored to your specific issue.
Products Cases

Company Profile

Certification

Related Products
ASTM D1298 Petroleum Products Density Tester
HZJD-2 Transformer Oil Tan Delta And Resistivity Tester
100 kV Automatic Insulation Oil Dielectric Strength ...
HZWS-X2 ASTM D6304 Coulometric Method Karl Fischer T...
HZ1721 Manual Surface Tensiometer Interfacial Tensio...
ASTM D971 Transformer Oil Interfacial Tension Measur...
Send Inquiry



