3000A Primary Current Injection Test Equipment
3000A Primary Current Injection Test Equipment Products Description I. Product Overview The HZ5373 3000A Primary Current Injection Test Equipment is our proprietary test equipment. Integrating domestic and international technological advantages, it employs CNC technology for enhanced...
3000A Primary Current Injection Test Equipment
Product Description
I. Product Overview
The HZ5373 3000A Primary Current Injection Test Equipment is our proprietary test equipment. Integrating domestic and international technological advantages, it employs CNC technology for enhanced anti-interference capability. Compared to previous generations, its adoption of low-power, high-capacity autotransformers and high-permeability iron-core converters enables superior power density, compact size, and reduced weight.
Primary Applications:
Primary busbar protection testing
Current transformer (CT) ratio verification
Industries Served: Power utilities, railways, petrochemical, metallurgy, mining, R&D, and electrical testing sites.
II. Technical Specifications
1. Key Parameters
| Item | Specification |
|---|---|
| Model | HZ5373 3000A High-Current Generator |
| Environmental Class | Category III per GB6587.1-86 (suitable for outdoor use) |
| Input Voltage | AC380V ±10% |
| Rated Power | 30 kVA |
| Output Current | AC 0–3000A (steplessly adjustable) • Digitally displayed on panel |
| Output Voltage | >10 V |
| Output Waveform | Standard sine wave • Ripple coefficient <0.3% • Exceeds power system standards |
| Measurement Accuracy | 0.3% (using 0.2S-class materials) • Continuous smooth adjustment • True RMS current/voltage display |
| Current Stability | 0.2% |
| Protections | Overcurrent, Overvoltage |
| Wiring Method | Customizable per requirements |
2. Operating Guidelines
Pre-Test Check
Verify wiring correctness and connection integrity.
Abnormal Conditions
Immediately power off if sparking, smoke, or startup failure occurs. Recheck wiring.
Output Terminal Requirement
Output terminals must form a closed loop; otherwise, no current will be generated.
Output Cables
Included: 2×3m test cables (standard).
External copper wire selection: ≥10 A/mm² cross-section.
Operating Duration
Design Capacity: 5 minutes (short-term duty).
Batch Testing: Limit to ≤2.5 minutes per operation.
Extended Tests (e.g., 30-min to 24-hr temperature rise): Use long-term thermal design parameters.
Products Cases

Company Profile

Certification

Related Products
Send Inquiry