No Partial Discharge Free Test Equipment

No Partial Discharge Free Test Equipment

Huazheng HZQW-10KVA/50kV PD-free test transformer uses a specialized structure and precision technology to maintain partial discharge levels within a narrow range. It is manufactured with high precision and is suitable for both field and laboratory applications, making it highly convenient to use.

 

No Partial Discharge Free Test Equipment Technical Specifications

 

1,Inflatable Type Testing Transformer:

Model:HZQW-10KVA/50kV 1set

The PD-free test transformer uses a specialized structure and precision technology to maintain partial discharge levels within a narrow range. It is manufactured with high precision and is suitable for both field and laboratory applications, making it highly convenient to use.

 

Technical Specifications:

 

Rated Capacity:10KVA Input Voltage:200V

Output Voltage:0-50KV PDAmount≤5PC

Output Current:200mA Accuracy:AC 1.5%

Power distortion: < 3% Insulation Dielectric:SF6 Gas

Dimension: O.D.:350mm,H. 0.8M Weight:55Kg

 

2.Main Technical Indicators

1. The equivalent capacitance ranges from 6pF to 250 μ F

2. Number of channels: single channel

3. Measurement range: 0.1pc-10000nc

4. Detection sensitivity and allowable current (see Table 1)

 

NO.

Tuning Capacitance Range

Sensitivity (PC)

(Unbalanced Circuit)

Effective Value Of Allowable Current

Unbalanced Circuit

Balance Circuit

1

0~25~100pF

0.02

30mA

0.25A

2

25~100~400pF

0.04

50mA

0.5A

3

100~400~1500pF

0.06

120mA

1A

4

400~1500~6000pF

0.1

0.25A

2A

5

1500~6000~25000pF

0.2

0.5A

4A

6

0.006~0.025~0.1μF

0.3

1A

8A

7

0.025~0.1~0.4μF

0.5

2A

15A

8

0.1~0.4~1.5μF

1

4A

30A

9

0.4~1.5~6.0μF

1.5

8A

60A

10

1.5~6.0~25μF

2.5

15A

120A

11

6.0~25~60μF

5

25A

200A

12

25~60~250μF

10

50A

300A

7R

Resistance

0.5

2A

15A

Table 1. Detection sensitivity and allowable current value of input unit

 

5. Elliptic scan time base

(1) Frequency 50/60, 100, 150, 200, 400Hz

(2) Rotation: 30 ° as the first gear, and can rotate 120 °

(3) Working method: ellipse sine wave straight line

 

6. Display unit

10.1 inch capacitive touch screen is used.

 

7. Amplifier

(1) 3dB low frequency fl:10, 20, 40KHz optional

(2) 3dB high frequency fh:80, 200, 300kHz optional

(3) Gain adjustment, rough adjustment 6, inter gear gain difference 20 ± 1dB, fine adjustment range >20db

(4) Asymmetry of positive and negative pulse response < 1dB

 

8. Time window

(1) Window width: adjustable, 5 ° ~ 170 ° at 50Hz

(2) Window position: each window can rotate 0 ° ~ 170 °

(3) Two time windows can be opened separately or simultaneously.

 

9. Peak pulse display

The touch screen displays 1 decimal place (10pc or more), 2 decimal places (less than 10pc), error: ± 3% (in full scale)

 

10. Test voltage display

(1) Range 150kV

(2) Input impedance: >1m Ω

(3) Display: touch screen display, display 1 decimal place

(4) Error: ± 1%

 

11. Test frequency display

Error: less than ± 1%

 

12. Zero standard system

Zero sign is consistent with all ellipse scanning frequencies

 

13. Structure

(1) Dimensions: 370mm (width), 460mm (depth), 215mm (height)

(2) Weight: about 12.5kg

 

 

Products Cases

 

HZ-20A04

 

Company Profile

 

af7e9172c2e3db1e6c4b786d81dd1ea7

 

Certification

 

Manufacturing-Price-Portable-Automatic-Current-Transformer-CT-PT-Testing-System 1

 

 

Related Products

 

 

image013001

 

 

 

 

 

 

 

Hot Tags: no partial discharge free test equipment, China no partial discharge free test equipment manufacturers, suppliers, factory, non-contact high voltage generator, high voltage impulse test set, high voltage dielectric test set, non contact high voltage generator, high voltage flash test set, digital high voltage test set

Send Inquiry

(0/10)

clearall