HZZGF 200kV 3mA DC High Voltage Tester
Working power supply:50HZ AC220V±10%
Voltage error:0.5%±2,minimum solution 0.1KV
Current error:0.5%±2,minimum solution 0.1µA
HZZGF 200kV 3mA DC Hipot Tester
DC High Voltage Tester Technical Parameters
|
Voltage (KV)/mA Current (mA) |
Control Box |
High-Voltage Unit |
|||
|
Rated Voltage |
Size (mm) |
Weight kg |
Size (mm) |
Weight kg |
|
|
200/2-5 |
200KV |
310 * 250 * 230 |
8kg |
1000 * 280 * 270 |
20kg |
|
output polarity |
Negative polarity, no-voltage start, linear continuous adjustment |
||||
|
working power supply |
50HZ AC220V±10% |
||||
Control Panel Of DC High Voltage Tester

1.Voltmeter: Displays the output voltage. Display unit: kV. Maximum display: 999.9 kV.
2.Ammeter: Displays the output current (including sample leakage current and air leakage current, etc.). Maximum display: 9999 µA, except for special models.
3.Power Socket: Single-phase AC 220V ±10%, 50 Hz power input.
4.MOA 75% Signal Light: The signal light is on when the voltage change is more than 75% of V1mA. The voltmeter displays the highest output voltage value, not the actual output voltage. Once the voltage regulation knob is turned back to zero, the light will turn off.
5.Aviation Socket: Please align the positioning pin and press the plug in, then tighten it clockwise to connect the socket. To disconnect, turn counterclockwise.
6.Note: Please hold the plug's metal rings tightly; do not grasp or pull the line. Improper disassembly or connection may shorten the lifespan of the connecting line.
7.Ground Terminal: Connect the ground wire to the grounding screw at the bottom of the generator.
8.MOA 75% Button: During the testing of zinc oxide lightning arresters, V_1mA is the high voltage value when the leakage current is 1 mA. Press the MOA 75% button to automatically drop the voltage to 75% of V_1mA. The conversion accuracy is better than 0.5%.
9.Voltage Rough Adjustment Knob: Clockwise adjustment increases the voltage, with a maximum of 1.1 Ve. Due to the needs of the internal self-test circuit and the non-zero start design, adjusting 3/4 of a clockwise turn will not produce voltage output when the potentiometer is returned to zero.
10.Voltage Fine Adjustment Knob: When the potentiometer is in the middle position, the adjustment range for the current value is between 3% and 8%.
11.Main Power Switch: Avoid turning off high voltage directly with this switch. Please use the HV switch first.
12.HV Switch: Turn up the HV switch to increase the voltage. Turn off the switch before shutting off the power after the test.
13.Fuse: AC inlet fuse. Please use a fuse with the matching current value.
14.Built-in Knob for Overvoltage Adjustment: The user can set and adjust the overvoltage value within the rated voltage range. The overvoltage value can be set statically without increasing the voltage. The error margin is 1%.
15.Overvoltage Indicator: When the output voltage exceeds the set voltage, the overvoltage protection mechanism will activate, shutting off the high voltage, and the overvoltage indicator light will turn on.
16.Overcurrent Indicator: When the load current exceeds 1.1 times the rated current or during a short circuit discharge, the indicator light will turn on, and the high voltage will shut off.
17.HV Indicator: When the high voltage switch is turned up under boost conditions, the high voltage indicator light is green. The setting of the overvoltage value can only be operated when the green light is off and the high voltage switch is off.



FAQ
1. When can I get a price quote?
You can contact us online or submit an inquiry. We typically provide a quote within 24 hours after receiving your request.
2. How do you handle after-sale service for overseas customers?
For issues occurring with our products, we offer:
12-month warranty coverage (see details below).
Online technical guidance to troubleshoot problems remotely.
Replacement parts shipped promptly based on your needs.
On-site support (if required): Our engineers can travel abroad to resolve critical issues.
3. What is the warranty period?
Our standard warranty period is 12 months (1 year). During this time, we provide:
Free technical support.
Replacement parts for manufacturing defects.
Solutions tailored to your specific issue.
Products Cases

Company Profile

Certification

Related Products
Hot Tags: HZZGF 200kV 3mA DC High Voltage Tester, China HZZGF 200kV 3mA DC High Voltage Tester manufacturers, suppliers, factory, intelligent dc high voltage test equipment, 60kv dc hipot tester, dc withstand voltage tester, high potential hipot tester, dc hipot tester 120kv, digital dc high voltage generator
Send Inquiry