How does a Partial Discharge Detector detect partial discharges in air - insulated equipment?
Jan 09, 2026
Partial discharge (PD) is a critical issue in air - insulated equipment as it can lead to insulation degradation, equipment failure, and even pose safety risks. As a trusted partial discharge detector supplier, we understand the importance of effectively detecting these partial discharges to ensure the reliable operation of air - insulated equipment. In this blog, we will delve into how a partial discharge detector detects partial discharges in air - insulated equipment.
Understanding Partial Discharges in Air - Insulated Equipment
Air - insulated equipment, such as switchgear, transformers, and cables, often operates under high - voltage conditions. Partial discharges occur when the electric field strength in a local area of the insulation exceeds the breakdown strength of the air, causing a localized ionization and discharge. These discharges can be caused by various factors, including insulation defects, contamination, and mechanical stress.
Partial discharges can manifest in different forms, such as corona discharges, surface discharges, and internal discharges. Corona discharges typically occur at sharp edges or points where the electric field is concentrated. Surface discharges happen along the surface of the insulation, while internal discharges occur within the insulation material.
Detection Principles of Partial Discharge Detectors
Electrical Detection Methods
One of the most common methods for detecting partial discharges is the electrical method. This method is based on the fact that partial discharges generate electrical pulses. A partial discharge detector can measure these electrical pulses using sensors.
The detector is connected to the air - insulated equipment through coupling capacitors or other electrical connections. When a partial discharge occurs, the electrical pulse is transmitted through the insulation and detected by the sensor. The detector then amplifies and analyzes the detected signal to determine the characteristics of the partial discharge, such as the magnitude, frequency, and phase of the discharge.
For example, our HZJF - 9104 Four Channels Partial Discharge Tester uses advanced electrical detection technology. It can accurately measure partial discharges in multiple channels simultaneously, providing comprehensive data for analysis. The tester has high sensitivity and can detect even small partial discharges, which is crucial for early detection of insulation problems in air - insulated equipment.
Ultrasonic Detection Methods
Ultrasonic detection is another important method for detecting partial discharges in air - insulated equipment. When a partial discharge occurs, it generates ultrasonic waves due to the rapid expansion and contraction of the gas in the discharge area.
An ultrasonic sensor can be placed near the air - insulated equipment to detect these ultrasonic waves. The sensor converts the ultrasonic waves into electrical signals, which are then processed by the partial discharge detector. Ultrasonic detection is particularly useful for detecting surface discharges and corona discharges, as these discharges often generate strong ultrasonic signals.
Our HZ - 9003C Portable Handheld Multifunctional Partial Discharge Tester is equipped with an ultrasonic detection function. It is portable and easy to use, allowing operators to quickly detect partial discharges in different locations of the air - insulated equipment. The tester can display the intensity of the ultrasonic signals, helping users to locate the source of the partial discharge.
Radio - Frequency Detection Methods
Partial discharges also generate radio - frequency (RF) electromagnetic waves. Radio - frequency detection methods use RF sensors to detect these electromagnetic waves. The RF sensors are designed to be sensitive to the frequencies generated by partial discharges.
The detected RF signals are then analyzed by the partial discharge detector. This method can provide information about the location and severity of the partial discharge. For example, by analyzing the amplitude and frequency of the RF signals, the detector can determine whether the partial discharge is a surface discharge, an internal discharge, or a corona discharge.
Our HZJF - 9041D 4 Channels Partial Discharge Detector is capable of radio - frequency detection. It can monitor multiple channels at the same time, providing a more comprehensive view of the partial discharge situation in the air - insulated equipment.


Signal Processing and Analysis
Once the partial discharge detector has detected the signals, it needs to process and analyze these signals to obtain useful information. The signal processing typically includes filtering, amplification, and digitization.
Filtering is used to remove noise and interference from the detected signals. Amplification is necessary to increase the strength of the signals so that they can be accurately measured. Digitization converts the analog signals into digital signals, which can be further processed by a microprocessor or a computer.
The analysis of the signals involves extracting features such as the amplitude, frequency, and phase of the partial discharge signals. These features can be used to identify the type and severity of the partial discharge. For example, a high - amplitude partial discharge signal may indicate a more severe insulation defect.
Localization of Partial Discharges
In addition to detecting partial discharges, it is also important to locate the source of the partial discharge. This can be achieved through various methods, such as time - of - flight measurement and triangulation.
Time - of - flight measurement involves measuring the time it takes for the partial discharge signal to reach different sensors. By comparing the arrival times of the signals at different sensors, the location of the partial discharge can be calculated. Triangulation uses the relative positions of multiple sensors and the angles of the incoming signals to determine the source of the partial discharge.
Importance of Regular Partial Discharge Detection
Regular partial discharge detection in air - insulated equipment is essential for preventing equipment failure and ensuring the safety of the power system. By detecting partial discharges at an early stage, operators can take timely measures to repair or replace the faulty insulation, thus avoiding costly breakdowns and power outages.
Moreover, partial discharge detection can also help to evaluate the aging and degradation of the insulation material. By monitoring the changes in the partial discharge characteristics over time, operators can predict the remaining life of the insulation and plan for maintenance and replacement in advance.
Contact Us for Your Partial Discharge Detection Needs
If you are in need of reliable partial discharge detection solutions for your air - insulated equipment, we are here to help. Our range of partial discharge detectors, including the HZJF - 9104 Four Channels Partial Discharge Tester, HZ - 9003C Portable Handheld Multifunctional Partial Discharge Tester, and HZJF - 9041D 4 Channels Partial Discharge Detector, are designed to provide accurate and reliable detection of partial discharges.
We are committed to providing high - quality products and excellent customer service. If you have any questions or would like to discuss your specific requirements, please feel free to contact us. Our team of experts will be happy to assist you in finding the most suitable partial discharge detection solution for your air - insulated equipment.
References
- Les Rencontres de la HVPD (High Voltage Partial Discharge). Proceedings of the international conference on partial discharges.
- IEEE Std 400.2 - 2013, IEEE Guide for Field Testing and Monitoring of the Insulation of Shielded Power Cable Systems.
- IEC 60270:2000, High - voltage test techniques - Partial discharge measurements.